Level 1 Specification
Technical Specification of Galvanization Strength Steel Wire Level 1
Norminal Diameter mm |
Diameter Deviation mm |
Stress at 1% Extension, min, MPa |
Ultimate Tensile Strength, min, MPa |
Elongation in 250mm, min, % |
Winding Test Mandrel Diameter mm |
Twisting Test Twisting Times, min | |
1,24< d ≤ 2,25 | ±0,03 | 1170 | 1340 | 3,0 | 1D | 18 | |
2,25< d ≤ 2,75 | ±0,04 | 1140 | 1310 | 3,0 | 1D | 16 | |
2,75< d ≤ 3,00 | ±0,05 | 1140 | 1310 | 3,5 | 1D | 16 | |
3,00< d ≤3,50 | ±0,05 | 1100 | 1290 | 3,5 | 1D | 14 | |
3,50< d ≤4,25 | ±0,06 | 1100 | 1290 | 4,0 | 1D | 12 | |
4,25< d ≤4,75 | ±0,06 | 1100 | 1290 | 4,0 | 1D | 12 | |
4,75< d ≤5,50 | ±0,07 | 1100 | 1290 | 4,0 | 1D | 12 |
Level 2 Specification
Technical Specification of Galvanization Strength Steel Wire Level 2
Norminal Diameter mm |
Diameter Deviation mm |
Stress at 1% Extension, min, MPa |
Ultimate Tensile Strength, min, MPa |
Elongation in 250mm, min, % |
Winding Test Mandrel Diameter mm | Twisting Test Twisting Times, min | |
1,24< d ≤ 2,25 | ±0,03 | 1310 | 1450 | 2,5 | 3D | 16 | |
2,25< d ≤ 2,75 | ±0,04 | 1280 | 1410 | 2,5 | 3D | 16 | |
2,75< d ≤ 3,00 | ±0,05 | 1280 | 1410 | 3,0 | 4D | 16 | |
3,00< d ≤3,50 | ±0,05 | 1240 | 1410 | 3,0 | 4D | 14 | |
3,50< d ≤4,25 | ±0,06 | 1170 | 1380 | 3,0 | 4D | 12 | |
4,25< d ≤4,75 | ±0,06 | 1170 | 1380 | 3,0 | 4D | 12 | |
4,75< d ≤5,50 | ±0,07 | 1170 | 1380 | 3,0 | 4D | 12 |
Level 3 Specification
Technical Specification of Galvanization Strength Steel Wire Level 3
Norminal Diameter mm |
Diameter Deviation mm |
Stress at 1% Extension, min, MPa |
Ultimate Tensile Strength, min, MPa |
Elongation in 250mm, min, % |
Winding Test Mandrel Diameter mm | Twisting Test Twisting Times, min | |
1,24< d ≤ 2,25 | ±0,03 | 1450 | 1620 | 2,0 | 4D | 14 | |
2,25< d ≤ 2,75 | ±0,04 | 1410 | 1590 | 2,0 | 4D | 14 | |
2,75< d ≤ 3,00 | ±0,05 | 1410 | 1590 | 2,5 | 4D | 12 | |
3,00< d ≤3,50 | ±0,05 | 1380 | 1550 | 2,5 | 4D | 12 | |
3,50< d ≤4,25 | ±0,06 | 1340 | 1520 | 2,5 | 4D | 10 | |
4,25< d ≤4,75 | ±0,06 | 1340 | 1520 | 2,5 | 4D | 10 | |
4,75< d ≤5,50 | ±0,07 | 1270 | 1500 | 2,5 | 4D | 10 |
Galvanized Layer
Norminal Diameter mm |
Area Density of galvanization, min, g/m2 |
|||
1,24< d ≤ 1,50 | 185 | |||
1,50< d ≤ 1,75 | 200 | |||
1,75< d ≤ 2,25 | 215 | |||
2,25< d ≤ 3,00 | 230 | |||
3,00< d ≤ 3,50 | 245 | |||
3,50< d ≤ 4,25 | 260 | |||
4,25< d ≤ 4,75 | 275 | |||
4,75< d ≤ 5,50 | 290 |
Determine Stress
Initial Setting for Determining Stress at 1% Extension
Norminal Diameter mm |
Initial Stress, MPa |
Initial Setting of Extensometer, (in 250mm) | |||||
1,24< d ≤ 2,25 | 100 | 0.125 | |||||
2,25< d ≤ 3,00 | 200 | 0.250 | |||||
3,00< d ≤4,75 | 300 | 0.375 | |||||
4,75< d ≤5,50 | 400 | 0.500 |